PixelmoorRequest a quote

(Architectural pixel lighting)

Media facade lighting for pixel-mapped building surfaces

Addressable fixtures, drivers and control for facades from 40 m² to whole tower planes.

Scroll
01 / 07
Works
Guzhen, Zhongshan
Shipped to
38 countries
Facades
126 delivered
Blue-hour facade of a glazed office block with addressable pixel points mapped across the mullion grid and a continuous wall-wash line under the cornice

(Fixtures)

Six addressable families

Pitch, protocol and IP class on every card — the three things the console and the fixing detail depend on.

  • Addressable point light: die-cast aluminium body, double gasket and a short cable with a waterproof connector on a dark grey table

    PM-DOT

    Addressable point light

    • 50 / 80 / 120 mm string spacing
    • DMX512 / RDM · SPI
    • IP68 · IK10 · 720 h salt spray
  • Wall-wash bar: matt dark-grey anodised aluminium profile with a gasketed end cap and a stainless bracket on a dark grey table

    PM-LINE

    Wall-wash and grazing bar

    • 300 / 600 / 1000 mm, field-cuttable
    • 0–10 V · DALI-2 · DMX512
    • IP66 · IK09 · 3-step MacAdam
  • Media pixel tube: opal polycarbonate diffuser showing a straight line of LEDs and threaded end caps, lit in a cyan to warm-white gradient

    PM-TUBE

    Media pixel tube

    • 12 / 24 / 48 px per metre
    • Art-Net / sACN · DMX512
    • 3 840 Hz · 16-bit · IP67
  • Transparent media mesh sample: P37.5 black pixel strips held upright with gloved hands, the open weave showing the surface behind

    PM-MESH

    Transparent media mesh

    • P25 / P37.5 / P50 mm
    • DVI / HDMI in · Art-Net / sACN out
    • up to 72% open area · IP65 front
  • Addressable flex strip coiled next to a cut length, copper pads and tape backing visible, LEDs lit in alternating cyan and warm white

    PM-STRIP

    Addressable flex strip

    • 60 / 144 LED per metre
    • WS2815 / APA102 / UCS2904
    • 12 / 24 / 48 V · 50 mm cut point
  • DIN-rail pixel controller beside its power supply on a dark grey surface, status LEDs and two network ports on the front panel

    PM-CTRL

    Pixel controller and driver

    • 12 000 px per port · 8 ports
    • Art-Net 4 · sACN E1.31 · KiNET
    • frame-sync across 12 units

View all fixtures

(Projects)

Facades lit and handed over

Four facades at the scale this company builds for.

City
Rotterdam, NL
Handed over
2024
Family
PM-TUBE / PM-CTRL
Scale
2 480 pixel tubes · 1 180 m² media ceiling
City
Manchester, UK
Handed over
2023
Family
PM-MESH / PM-CTRL
Scale
P37.5 mesh · 640 m² transparent media
City
Singapore, SG
Handed over
2025
Family
PM-LINE / PM-DOT
Scale
3 100 linear bars · 26 km pixel run
City
Abu Dhabi, AE
Handed over
2024
Family
PM-DOT / PM-CTRL
Scale
18 400 addressable points · 4 facade planes

View the project record

Media ceiling of a transit concourse: rows of pixel tubes hanging along the structural beams, lit in cyan and warm white
Transparent media mesh across a stadium west facade, steel structure and stairwell still visible through the open weave
Light rail interchange platform: continuous wall-wash bars lighting the concrete soffit, pixel points between the columns
Waterfront towers at night with four facade planes of addressable pixels and a faint reflection on the water

(Engineering)

From photometric study to commissioning

Three things happen between your drawing and a lit facade. Each one is done in house.

  1. 001//

    Photometric study and mock-up

    The design file decides the optics. We import the layout, pick the beam for the throw distance and send the IES or LDT back for DIALux or AGi32 before anything is cut.

    • IES / LDT per family
    • DIALux · AGi32
    • 1:1 mock-up panel
    • 3-step MacAdam binning
    Darkroom measurement bench: a linear fixture clamped in a goniometer arm, an integrating sphere half open beside it, instrument screen unreadable
    4 m goniometer arm, darkroom run on every family
  2. 002//

    Configured to the facade drawing

    Nothing here is cut to a catalogue length. Pitch follows the viewing distance, segments follow the mullion grid, brackets are drawn to the fixing detail — including the dies for a bent corner.

    • P25 / P37.5 / P50 pitch to distance
    • field-cuttable 300 / 600 / 1000 mm
    • brackets drawn to the fixing detail
    • profile dies in house
    Installation detail behind a curtain wall: an anodised aluminium fixture clipped to the mullion bracket, waterproof connector and cable tied into the profile channel
    ±1.5 mm bracket tolerance held to the mullion grid
  3. 003//

    Commissioning and phased delivery

    The chain has to hold up on site. One controller drives 12 000 pixels per port across Art-Net, sACN or RDM; we ship in phases that match the site programme and keep spares for the run.

    • 12 000 px per port · 8 ports
    • Art-Net 4 · sACN E1.31 · DMX512-A / RDM
    • 3 840 Hz refresh · 16-bit grey
    • phased delivery, spares held
    Outdoor control cabinet interior: two pixel controllers and a power supply on DIN rail, bundles of pixel and network cable landed on terminals
    <1 frame drift across 12 synchronised controllers

(Factory)

From extrusion to 200-hour ageing

Assembly and ageing hall: three aisles of powered ageing racks with pixel fixtures lit, two workers in dark grey workwear recording readingsEvery fixture is extruded, potted and aged here before it ships.

Profile extrusion and SMT driver assembly, potting and sealing, a darkroom photometric run, then 200 hours on the ageing racks — the same building the spares come from.

Floor area
16 800 m²

Guzhen, Zhongshan — extrusion, SMT and darkroom under one roof

Capacity
1.4 M fixtures / year

238 production · 26 QC · 31 engineering, 78% exported

  • CE · EMC + LVD
  • FCC Part 15B DoC
  • RoHS 2011/65/EU
  • ErP + EPREL
  • LM-79
  • LM-80 / TM-21

See the factory

(Before you spec)

Seven questions before spec

The ones that come back in the second email, answered here instead.

Facade lighting engineer in dark grey workwear standing beside an ageing rack, turned towards the fixtures rather than the camera

More questions? Ask an engineer

Send the facade drawing
When do we get the IES and LDT files?

With the quotation, for the families in the scheme. Per-configuration files follow the mock-up panel, because the beam changes once the bracket angle is fixed.

Art-Net or sACN — and how many pixels per port?

Both, plus DMX512-A and RDM on the same controller. 12 000 pixels per port across eight ports, 16 universes per unit, frame-synced with under one frame of drift.

What IP and IK class, and how does the wiring stay dry?

IP66 for the linear family, IP67 for tubes, IP68 for point light with IK09 to IK10. Every joint is a gasketed M12 or a potted inline connector; the harness is specified with the bracket drawing.

How tight is batch-to-batch colour?

Three-step MacAdam bins held across the order, and the LM-79 report for the reference CCT ships with the file pack. Mixed bins are quoted separately, never substituted.

Can you build to a bent or irregular facade?

Yes — pitch, segment length, bracket and profile die are all set from the facade drawing. Send a DWG or a dimensioned elevation and we quote the tooling with the fixtures.

What is the lead time, and can it be phased?

25 to 35 days for project quantities, split into drops that match the site programme. Pilot batches run 20 to 25 days; samples with a photometric report run 10 to 14 days.

Warranty and spares?

Five years on fixtures, three on controllers and drivers. Spares for the pixel run are held for the project and shipped from the same production batch.

See photometric files

(Request a quote)

Quotation and photometric pack in 48 h

Pixelmoor Lighting Technology Co., Ltd.
Zhongshan, China

sales@pixelmoor.com
WhatsApp

Send the facade drawing

Facade size, viewing distance and the console you run — that is all we need.

Sent only to the engineering team that answers it — see our privacy note. No newsletter.